2.4 Recycling/Disposal
Disposing of this product and its packaging in the correct manner protects people and the environ-
ment. Please dispose of the units in accordance with local regulations and at the collecting points
designed for this purpose.
The battery and the BRITA FlowMeter must not be burnt and must not be disposed of in domestic
waste; please hand in the batteries and the display unit to the collecting points designed for this pur-
pose in line with the local regulations. See also Chapter 11.
Used fi lter cartridges can be returned to the BRITA addresses listed (see back of the cover).

3 Operating and Safety Instructions

3.1 Qualifi ed Personnel
Installation and maintenance of the fi lter system may be carried out only by trained and authorised
personnel.
3.2 Correct Use
The product can only operate perfectly and safely if it is installed, used and serviced in the manner
described in this handbook.
Note: the fi lter system and system-specifi c PURITY Steam fi lter cartridges may only be used
upstream from end devices such as hot air steamers, combi ovens and conventional ovens.

3.3 Liability Exclusion

Installation must be performed precisely in accordance with the instructions in this handbook.
BRITA shall not be held liable for any damage, including subsequent damage, arising from the incor-
rect installation or use of the product.
3.4 Specifi c Safety Information
Only water of drinking water quality may be used as intake water for the BRITA water fi lter sys-
tem. The BRITA water fi lter system is only suitable for cold water use within the water intake
temperature stated in Chapter 12. No microbiologically impaired water or water of unknown
quality may be used without prior appropriate disinfection.
If there are offi cial instructions to boil tap water, the fi lter system must be decommissioned.
When the requirement to boil water comes to an end, the fi lter cartridge must be replaced and
the connections cleaned.
For hygiene reasons, the fi lter material of the cartridge is subjected to a special treatment with
silver. A small quantity of silver, which is harmless to health, may be released into the water.
This is in compliance with the World Health Organisation (WHO) recommendations for drinking
water. At most, the values stated in the Codes Alimentarius Austriacus may be exceeded.
Note for people with kidney disease or dialysis patients: During the fi lter process the potassium
content may be increased slightly. If you suffer from kidney disease and/or have to stick to a
special potassium diet, we recommend prior agreement with your doctor.
The water fi ltrate is classifi ed in Category 2 according to DIN EN 1717.
BRITA recommends that the fi lter system not be decommissioned for a long period. If the
BRITA PURITY Steam fi lter system is not used for several days (two to three days), we recom-
mend that the fi lter system be fl ushed with at least X litres according to the table below. After
stagnation periods of over four weeks, the fi lter should be fl ushed with at least Y litres or else
replaced. Please also note that the maximum usage period of the fi lter cartridge is twelve
months (Chapter 6).
Filter system
PURITY 450 Steam
PURITY 600 Steam
PURITY 1200 Steam
The fi lter system is not resistant to heavily concentrated cleaning agents (e.g. bleach, chlorin-
ated solvents, heavy oxidants) and must not come into contact with them.
Flush quantity X
after 2–3 days stagnation
6 litres
12 litres
24 litres
Flush quantity Y
after 4 weeks stagnation
30 litres
60 litres
120 litres