MANUAL FUNCTION / PULSE FUNCTION
If the instrument is in OFF position press button (3) once to enter into MANUAL function; ON/OFF
LED and MANUAL LED are illuminated, all laser lines are on. Now the instrument can be used in slope
mode, compensator alarm is off.
Press button (3) a second time to switch on receiving mode; pulse LED is illuminated, laser lines are
weaker. Receiving mode in MANUAL function also possible.
Press button (3) a third time to deactivate all active functions (MANUAL function, receiving mode,
instrument off).
If the instrument is in ON position press button (3) to switch on receiving mode, press button (3) again
to switch it off.
USE WITH RECEIVER (OPTIONAL)
To extend the working range of the laser or at unfavourable light conditions 360° LinerPoint HP can be
used with the receiver FR 55-M. Receiver FR 55-M is optional.
Note:
When using pulse function laser lines will be a little bit weaker than usual.

ACCURACY CHECK

Set up instrument about 5 m from a wall. Switch instrument on and wait until selfleveling procedure
is completed. Mark laser line A on the wall. Turn instrument by 90° and mark laser lines B, C and D on
the wall. Measure distance between points A, B, C and C. If largest distance between two points is
≤ 2 mm instrument must be adjusted. Please contact your local dealer.