36-B
Same process for 3rd correction point.
Program starts again normally after the 3 correction points have been entered.
0 knots corresponds to zero correction.

5.4 CHANGE OF CIRCULAR BARGRAPH SCALE

The ANTHEA has an automatic analog scale switch over allowing an optimum reading.
When the ship speed overpass 25 Knots, the log is automatically switching-over on the 50
Knots scale.
The log will switch-over again on the 25 Knots scale when speed is inferior to 24 Knots
(Hysteresis of 1 Knot).

6. ERROR MESSAGES

Any possible fault of log is detected by a permanent self test and displayed on the 2 x 16-
digit lines LCD screen.
Possible error messages are:
- "Measure not valid"
- "Sensor current"
- "Log interface"
- "Faulty memory"
Measure not valid:
This message appears in the event of a faulty analog component, or when sensor is out of
water.
Sensor current:
This message appears when sensor is no more current on sensor. Check the sensor
(inductor) connections.
Faulty memory:
This message appears when the EPROM memory happens to be erased.
Log interface:
This message appears after a transmission fault between the display board and the
measuring board.
If any of these messages appears, please contact one of AVANTIX/BEN engineers.
97MU001-F