1.2 MAIN FEATURES
Watertight main cabinet made of a molded alloy, installed on a bracket or flush
mounted.
IP 65 watertightness
Size: 244 x 164 x 95 mm
LCD screen for :
Speed display on circular bargraph
Digital speed display:
Covered distance/reset:
Double scale:
Test and alarm
Electromechanical mile totalizer without reset
6 digits - Unit: 0.1 nautical mile
LCD screen, 2 lines, 16 digits for :
Alarms adjustment (high, low)
3-linearization-point adjustment
Error message display
Display of:
High and low speed alarm display
Brightness control
Permanent self-test
Automatic gain control
Accuracy (after calibration) 2 % on the LCD display (The results are guaranteed
for a depth > 3 meters)
For a roll leading to an oscillation of 3 Knots of the displayed speed with a period
of 4 seconds, the damping function of the equipment reduce this oscillation to a value
inferior of 0,3 Knots.
Variation of the displayed speed according to water temperature is less than 0,2
Knot.
Variation of the displayed speed according to water salinity is less than 0,2 Knot.
Note: maximum length between sensor and electronic unit = Please refer to drawing
"Cabling and installation configuration".
ANTHEA OPERATION AND INSTALLATION MANUAL
This document is Avantix property and cannot be copied or transmitted without the company's authorization
0,1 knot definition
99999,9
25 or 50 knots
longitudinal speed
transversal speed
for XY version (optional)
resultant speed
drift angle
97MU001-F