Switch "TEST" on and wait a few seconds till speed display is stabilized.
Note test value.
Calculate new test value: for example:
Test value = 18 knots
New value =
18 knots -
Put-on strapp E11
Adjust potentiometer R56 so as to bring test value back to 16,2 knots.
Take off strapp E11
so as to set adjustment
Switch on "Normal" position (N).
ANTHEA OPERATION AND INSTALLATION MANUAL
This document is Avantix property and cannot be copied or transmitted without the company's authorization
18 x 10
= 16,2 knots
100