READING THESE INSTRUCTIONS IS IMPORTANT FOR PERSONAL SAFETY. READ THE FOLLOWING REMARKS CAREFULLY BEFORE
PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
ORIGINAL INSTRUCTION MANUAL. NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING
ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM. SAVE THESE INSTRUCTIONS FOR FUTURE
USE. THE ORIGINAL INSTRUCTIONS AND RELATIVE UPDATES ARE AVAILABLE IN DIGITAL FORMAT FROM THE WEBSITE WWW.CARDIN.IT.
• These instructions are aimed at professionally qualified 'INSTALLERS OF
ELECTRICAL EQUIPMENT' and must respect the local standards and
regulations in force.
All materials used must be approved and must suit the environment in
which the installation is situated and all maintenance operations must be
carried out by professionally qualified technicians.
• This appliance must be used exclusively for the purpose for which it has
been made. 'i.e. for the automation of hinged gates' with one or two
gate leaves.
CAUTION! Mechanical stop buffers must be installed in both the
closing and opening positions.

IMPORTANT SAFETY INSTRUCTIONS

It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main road
to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property and not on the public
side of the gate. The gates must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles are passing.
Pedestrians should use a separate entrance.
The controls must be installed at a height between 1,5 and 1,8 m and in a location
4)
not accessible to children. Controls installed externally must be protected by
a safety device inhibiting unauthorised use.
5)
At least two warning signs (similar to the example on the
right) should be placed, where they can be easily seen
by the public, in the area of the system of automatic
operation. One inside the property and one on the public
side of the installation. These signs must be indelible and not hidden by any
objects (such as tree branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must not be allowed
to play within the area of a gate installation. If possible include this in the warning
signs.
7) Whenever a fully open gate leaf comes within at 500 mm of a fixed structure the
space must be protected by an anticrush buffer.
8) You are advised to protect the system's lateral access points with pairs of (FS)
photocells connected to the stop input, see installation example, component 14
on page 2.
9) If you have any questions about the safety of the gate operating system, do not
install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
BL824M self-locking Master reduction unit with an incorporated encoder and
on-board electronics.
BL824S self-locking Slave reduction unit with an incorporated encoder without
on-board electronics.
• Direct current drive motor max. 24 Vdc.
• Permanently lubricated four-stage epicycloid reduction unit. Externally
activated manual release system (Cardin patent) managing the release of
the gears form the gate (emergency manoeuvre).
• A plastic framework is fixed to the reduction unit chassis and houses the
electronic programmer, the toroidal transformer and the radio frequency
module. The battery charger and special Cardin emergency NiMH batteries
are optional.
• Motor support base in cast aluminium.
ACCESSORIES
BL824ARM Standard articulated arm (curved) in spray-painted cast aluminium.
BL824DRM Straight arm with sliding guide in spray-painted cast aluminium.
ATTENTION! IMPORTANT SAFETY INSTRUCTIONS
AUTOMATIC OPENING
APERTURA AUTOMATICA
FERMETURE AUTOMATISÉE
AUTOMATISCHER ÖFFNUNG
Installation company:
Serial number:
Product model:
Installation date:
®
Weight in kg:
riello elettronica group
ZVE: 572 - Mod: 04-09-2017
USER INSTRUCTIONS
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has
expired it must be disposed of separately from other rubbish. The
user is therefore obliged to either take the product to a suitable
differential collection site for electronic and electrical goods or
to send it back to the manufacturer if the intention is to replace
it with a new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials. Illicitly disposing of this
product by the owner is punishable by law and will be dealt with according
to the laws and standards of the individual member nation.
During the opening/closing manoeuvre check for correct operation and activate
the emergency stop button in case of danger. During blackouts the gate can
be released and manually manoeuvred using the supplied release key (see
manual release page 10).

INSTALLATION INSTRUCTIONS

The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed in a location not accessible to children and outside
the opening range of the gate.
Before starting the installation of the system check that the structure which
is to be automated is in good working order and respects the local standards
and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary reinforce
the structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which maintain
unaltered friction characteristics over a period of time and are suitable for
temperatures of -20 to +70°C.
• Check the safety measures between the fixed and moving parts:
- a minimum space of 30 mm must always be left along the entire distance
between the gate and the support column measured throughout the entire
opening angle of the gate.
- make sure that the space between the bottom of the gate and the pavement
never exceeds 30 mm throughout the entire opening angle of the gate.
• The surface of the gate must not feature openings which allow a person's
hand or foot to pass through.
• Check the exact positioning of the pivots, and their good working order (the
upper and lower hinges/pivots must be aligned on the same axis).
• Work out the run of the cables according to the command and control
devices fitted and make sure the system conforms to the local standard
and regulations in force (see installation example).
• Check that the appliance is suitable for the size, weight and duty cycle of
the gate to which it is to be applied (see duty cycle on page 20).
ASSEMBLY PROCEDURE
The unit may be positioned either to the right or to the left of the passageway:
• Move the gate/s to the closed position.
• Choose the value "A" (fig. 4) according to the required opening angle and
work out (depending on the structural characteristics of the gate) at what
height the front bracket will be fitted to the gate.
• Once the position has been established pass the connecting, power and
safety device cables "C" through the opening "D" (fig. 6) in the column and
fasten down the motor support plate using four M8 screws and steel Ø14
rawlplugs "V1" or using 4 tie rods M8 with washers and nuts "V2". Make
sure that the aluminium base "E" (fig. 6) is perfectly square.
• Pass the cables "C" (fig. 7) through the cable clamp "F" and fasten them
inside the base using the screw "G".