3.4.13 The AES coding mode menu {AES}
This menu is used to select the insertion mode in the digital outputs of the channel status
informations: consumer or professional mode can be selected. In consumer mode sample rate, and
in professional mode lock, sample rate, word length, origin and destination parameters follow the
user selection. This parameter can be accessed by remote control.
Procedure
• Press [+] or [-] displays the {AES} menu,
• Press [SEL] displays O-1&2, use [+] or [-] to scroll through the available channels O-1&2, O-1, O-2
(AAP-712i only).
• Press [SEL] validates the output and displays MODE,
• Press [SEL] again displays the current mode PRO or CONS, use [+] or [-] to change the mode,
• Press [SEL] to store the new parameter and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ ESC ].
3.4.14 The Origin message Menu {ORIG}
This menu enables edition of message corresponding to the origin of the signal, coded with 4 ASCII
characters within the carrier. This parameter can be accessed by remote control.
Procedure
• Press [+] or [-] displays the {ORIG} menu,
• Press [SEL] displays O-1&2, use [+] or [-] to scroll through the available channels O-1&2, O-1, O-2
(AAP-712i only).
• Press [SEL] validates the output and displays CHR1, use[ + ] or [ - ] to scroll through the available
characters to modify CHR1, CHR2, CHR3, CHR4.
• Press [SEL] displays the current value, use[ + ] or [ - ] to scroll through the 96 available ASCII
characters.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ESC].
Guide to installation & Operation
AAP-711i - AAP-712i
23