Electrical Installation; Aes3 110 Ω Rear Panel; Aes3-Id 75 Ω Rear Panel - Miranda AAP-711i Notice D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.4 Electrical installation

When connecting the AAP-711i or AAP-712i to external equipment, make sure that all digital
connections are point-to-point. Refer to the figure below and to the following descriptions for a
complete AAP-711i or AAP-712i installation.
This equipment is conform to the CEE 89 / 336 directive and operation is subject to the
following two conditions:
1- this equipment may not cause harmful interference according to EN 50081-1
rules.
2- this equipment must accept any interference received, according to EN
50082-1 rules.
Precaution of use:
Several components included are very static-sensitive. To avoid damaging those components,
be sure to respect the following rules:
1- Before touching any component or any other element of the card make sure
to reduce any static electricity on your person. One way to do this is to touch a
surface connected to ground, or to wear a wrist strap attached to ground.
2- when handling card, hold it by the edges avoiding touching the components.
2.4.1 AES3 110 Ω rear panel
Figure 4: Quartet-A110 or Symphonie-R-A110 rear panel
ANALOG
26 point HD female socket
REF.IN
BNC jacks
AES
15 point HD female socket
REM
RJ45-10 socket
2.4.2 AES3-id 75 Ω rear panel
Figure 5: Symphonie-R-AX rear panel
ANALOG
26 point HD female socket
REF.IN
BNC jacks
OUT1, OUT2
BNC jacks
REM
RJ45-10 socket
Guide to installation & Operation
Analog audio inputs & outputs
Reference input with passive loop-through
Digital audio outputs and AES3 reference input
GPI alarm outputs, delay remote control inputs
REF.IN
OUT1
Analog audio inputs & outputs
Reference input with passive loop-through
Digital audio outputs
GPI alarm outputs, delay remote control inputs
OUT2
NC
AAP-711i - AAP-712i
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aap-712i

Table des Matières