Guide to installation & Operation
3.4.14 The channel status mode menu {CHST}
This is a selector for the coding mode (pro/consumer) and the origin and destination parameters. They
can either follow the digital input (D-IN) or take the local value (LOCL) entered with the {AES}, {ORIG}
and {DEST} menus. In the (AUTO) position the channel status mode will follow the {SEL} value:
(LOCL) for analog inputs and (D-IN) for digital (AES or Abus) inputs. This parameter can be accessed
by remote control.
Procedure
• Press [+] or [-] displays the {CHST} menu,
• Press [SEL] displays O-1&2, use [+] or [-] to scroll through the available channels O-1&2, O-1, O-2
(UAP-712i only).
• Press [SEL] validates the channel and displays, use [+] or [-] to scroll through the available values
AUTO, D-IN or LOCL
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ESC].
3.4.15 The AES coding mode menu {AES}
This menu is used to select the insertion mode in the digital outputs of the channel status informations:
consumer or professional mode can be selected. In consumer mode the sample rate parameter, and in
professional mode the lock, sample rate, word length, origin and destination parameters follow the user
selection. This parameter can be accessed by remote control.
Procedure
• Press [+] or [-] displays the {AES} menu,
• Press [SEL] displays O-1&2, use [+] or [-] to scroll through the available channels O-1&2, O-1, O-2
(UAP-712i only).
• Press [SEL] validates the output and displays MODE,
• Press [SEL] again displays the current mode PRO or CONS, use [+] or [-] to change the mode,
• Press [SEL] to store the new parameter and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ ESC ].
3.4.16 The Origin message Menu {ORIG}
This menu enables edition of message corresponding to the origin of the signal, coded with 4 ASCII
characters within the carrier. This parameter can be accessed by remote control.
Procedure
• Press [+] or [-] displays the {ORIG} menu,
• Press [SEL] displays O-1&2, use [+] or [-] to scroll through the available channels O-1&2, O-1, O-2
(UAP-712i only).
• Press [SEL] validates the output and displays CHR1, use[ + ] or [ - ] to scroll through the available
characters to modify CHR1, CHR2, CHR3, CHR4.
• Press [SEL] displays the current value, use[ + ] or [ - ] to scroll through the 96 available ASCII
characters.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ESC].
26
x UAP-711i/712i