3.4.10 The monitoring menu {MNTR}

The module can be used as an analog audio processor with digital outputs or as an analog to digital
audio converter with analog outputs. The channel 1 analog outputs can be used in two ways: either,
like channel 2 analog outputs, as an analog image of the digital output 1 or as a stereo monitoring
output. This menu adds monitoring controls to the channel 1 analog outputs: when enabled, it gives
access to the relevant functions: alarm activation, sources selection, listening levels and muting. If
the monitoring mode is turned off these controls are ineffective. These parameters can be accessed
by remote control.
To enable or disable the monitoring menu
• Press [+] or [-] displays {MNTR},
• Press [SEL] displays ENAB,
• Press [SEL] again displays the current value, use [+] or [-] to scroll through the available values
OFF and ON.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
To use the monitoring outputs
Monitoring alarms can be activated or not. The source selection gives the choice between stereo
L&R1, stereo L&R2, mono L1, mono R1, mono L2 and mono R2. The levels can be adjusted from –
96 dB to +12 dB for the two channels or separately, a dedicated mute control is provided.
• Press [+] or [-] displays {MNTR},
• Press [SEL] displays ENAB, use [+] or [-] to scroll through the available parameters ENAB, MALM,
MSEL, MLVL, MMUT
• Press [SEL] displays MALM,
• Press [SEL] again displays the current value, use [+] or [-] to scroll through the available values
OFF and ON.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• Press [SEL] again with MSEL displayed gives the current selection, use [+] or [-] to scroll through
the available values L&R1, L&R2, L1, R1, L2, R2.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Press [SEL] again with MLVL displayed shows L&R, use [+] or [-] to scroll through the available
channels L&R, L, R.
• Press on [SEL] validates the channel and displays the current monitoring level value. Use [+] to
increase or [-] to decrease the value. For a quicker response, keep the push button depressed.
• Press [SEL] to return to the previous menu and to store the new parameter, or [ESC] to return
without updating the parameter,
• Press [ESC] to return to the previous menu
• Press [SEL] again with MMUT displayed shows L&R, use [+] or [-] to scroll through the available
channels L&R, L, R.
• Press [SEL] validates the channel and displays the current value, use [+] or [-] to scroll through the
available values OFF or ON.
• Press [SEL] to return to the previous menu and to store the new parameter, or [ESC] to return
without updating the parameter,
• Press [ESC] to return to the previous menu,
• To turn off the display, press [ESC].