3.4.8 The output level adjustment menu {OLVL}

This menu enables to adjust each output level. This adjustment is made within a range of -96 dB to
+12 dB by 0.5 dB steps. Any overload condition is displayed on the corresponding led. These
parameters can be accessed by remote control.
Procedure
• Press [+] or [-] displays {OLVL},
• Press [SEL] displays O-1&2, use [+] or [-] to scroll through the available channels O-1&2, O-1, O-2
(AAP-712i only).
• Press [SEL] validates the output and displays L&R, use [+] or [-] to scroll through the available
channels L&R, L, R.
• Press on [SEL] validates the channel and displays the current level value. Use [+] to increase or [-]
to decrease the value. For a quicker response, keep the push button depressed.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ESC].

3.4.9 The mute (AES silence) menu {MUTE}

A mute command starts with a soft mute; it is followed by an AES silence at the digital outputs. The
corresponding TEST led will light in yellow. Follow these steps to disable or enable mute functions.
These parameters can be accessed by remote control.
Procedure
• Press [+] or [-] displays {MUTE},
• Press [SEL] displays O-1&2, use [+] or [-] to scroll through the available channels O-1&2, O-1, O-2
(AAP-712i only).
• Press [SEL] validates the output and displays L&R, use [+] or [-] to scroll through the available
channels L&R, L, R.
• Press [SEL] validates the channel and displays the current value, use [+] or [-] to scroll through the
available values OFF or ON.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ESC].