3.4.3 The channel swapping Menu {SWAP}
This menu is used to configure the full four inputs / four outputs switcher (two inputs / two outputs for
AAP-711i). Each output can be individually assigned to any input, and one input can be routed to
more than one output. These parameters can be accessed by remote control.
Procedure
• Press [+] or [-] displays {SWAP},
• Press [SEL] displays the channel 1 left output: >-1L, use [+] or [-] to scroll through the available
outputs >-1L, >-1R, >-2L, >-2R.
• Press [SEL] validates the output and displays the current input, use [+] or [-] to scroll through the
available Inputs I-1L, I-1R, I-2L, I-2R.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ESC].
Guide to installation & Operation
AAP-711i - AAP-712i
17