3.4.4 The channel swapping Menu {SWAP}
This menu is used to configure the full four inputs / four outputs switcher (two inputs / two outputs for
UAP-711i). Each output can be individually assigned to any input, and one input can be routed to more
than one output. The relevant channel status bits are swapped with the audio content. These
parameters can be accessed by remote control.
Procedure
• Press [+] or [-] displays {SWAP},
• Press [SEL] displays the channel 1 left output: >-1L, use [+] or [-] to scroll through the available
outputs >-1L, >-1R, >-2L, >-2R.
• Press [SEL] validates the output and displays the current input, use [+] or [-] to scroll through the
available Inputs I-1L, I-1R, I-2L, I-2R.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ESC].
3.4.5 The pre-mix level adjustment menu {LVL}
This menu enables to adjust each level at the switcher outputs. This adjustment is made within a range
of -96 dB to +12 dB by 0.5 dB steps; any overload condition is displayed on the corresponding led.
These parameters can be accessed by remote control.
Procedure
• Press [+] or [-] displays {LVL},
• Press [SEL] displays 1&2, use [+] or [-] to scroll through the available channels 1&2, 1, 2. (UAP-712i
only)
• Press [SEL] validates the channel and displays L&R, use [+] or [-] to scroll through the available
channels L&R, L, R.
• Press on [SEL] validates the channel and displays the current level value. Use [+] to increase or [-] to
decrease the value. For a quicker response, keep the push button depressed.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ESC].
3.4.6 The phase inversion menu {PHSE}
This menu enables individual phase inversion of signals issued from the pre-mix level adjustment stage.
These parameters can be accessed by remote control.
Procedure
• Press [+] or [-] displays {PHSE},
• Press [SEL] displays 1&2, use [+] or [-] to scroll through the available channels 1&2, 1, 2. (UAP-712i
only)
• Press [SEL] validates the channel and displays L&R, use [+] or [-] to scroll through the available
channels L&R, L, R.
• Press [SEL] validates the channel and displays the current value, use [+] or [-] to scroll through the
available values: NORM or INV.
• Press [SEL] to store the new parameter, and to return to the previous menu
• Or press [ESC] to return to the previous menu without updating the parameter.
• To turn off the display, press [ESC].