Device description ARTROMOT®-E2
Figures ARTROMOT®-E2
Symbol overview ARTROMOT®-E2/-E2 compact
Figures ARTROMOT®-E2 compact
Device description ARTROMOT®-E2 compact
1. How to use the CPM device
1.1 Fields of application
1.2 Therapy objectives
1.3 indications
1.4 Contraindications
2. Description of the ARTROMOT®-E2/-E2 compact
2.1 description of the ARTROMOT®-E2 device components
2.2 description of the ARTROMOT®-E2 compact device components
2.3 description of the programming unit
2.4 Explanation of symbols
2.5 Explanation of symbols (connections and nameplate)
3. Safety information
4. Device setup
Note: See device description on pages II / III and VIII / IX
4.1 Connecting the ARTROMOT®-E2/-E2 compact, performance check
4.2 Adjusting the device to the patient
5. Setting the treatment values
5.1 General information on programming the ARTROMOT®-E2/-E2 compact
5.2 Programming the ARTROMOT®-E2/-E2 compact
5.3 Therapy parameter details
5.4 Application and programming examples
6. Care, Maintenance, Transport, Conversion
6.1 Care
6.2 Maintenance (fuse replacement)
6.3 Transport
6.4 Conversion
7. Environmental Protection Statement
8. Specifications
9. IEC 60601-1-2:2007 and IEC 60601-1-11:2010
9.1 Electromagnetic emissions
9.2 Electromagnetic immunity
9.3 Recommended separation distances
10. Contact
11. Technical service
11.1 Technical hotline
11.2 shipment
11.3 spare parts
12. Declaration of conformity
48
1. How to use the CPM device
II
1.1 Fields of application
IV
V
VII
The ARTROMOT®-E2/-E2 compact is a
motor-operated Continuous Passive Mo-
VIII
tion (CPM) device providing motion to the
elbow joint.
49
49
suitable for use in hospitals, clinics,
49
general practices and rental services, it is
49
an important supplement to medical and
49
therapeutic treatment.
50
50
1.2 Therapy objectives
51
52
55
CPM therapy with the ARTROMOT®-E2/-E2
56
compact is mainly used to prevent the
58
negative effects of immobilization, to allow
patients to regain painless mobility of joints
62
at an early stage and to promote healing and
achieve a positive functional result.
62
63
Other objectives of therapy include:
66
− improvement of joint metabolism
66
68
− prevention of joint stiffness (arthrofibrosis)
69
− promotion of the regeneration and healing
77
of cartilage and damaged ligaments
79
− faster hematoma/fluid resorption
79
− improved lymph and blood circulation
79
− thrombosis and embolism prophylaxis
81
84
86
86
88
88
89
91
92
93
93
93
93
94
1.3 Indications
The CPM device is indicated in the treat-
ment of most injuries and postoperative
conditions and diseases of the elbow joint.
Examples:
− joint distortion and contusion
− arthrotomy and arthroscopy procedures
in combination with synovectomy,
arthrolysis or other intra-articular
interventions
− all types of arthoplasty
− mobilization of joints in anesthetized
patients
− exercise-stable fractures after surgery
and pseudoarthrosis
− endoprosthetic implants
− myoplasty
− corrective osteotomy
1.4 Contraindications
Do NOT use the ARTROMOT®-E2/-E2
compact on patients with:
− acute inflammatory processes in the
joints, unless on the order of a physician
− spastic paralysis
− unstable osteosynthesis
49