12.2 ALIGNMENT

Remove the cover and switch on the power to the unit
Set the parameters for the various functions
Adjust the angle of the optics
Press the TEST button on the RX card for 3 seconds until the buzzer gives the acoustic signal twice, together with
two flashes of the long-range LED, for the start of calibration.
Repeat the operation on the receiver of the second barrier.
Point the optics on the TX column towards the RX column, adjusting them vertically and horizontally with the
adjustment screws (horizontal and vertical) until maximum alignment is found.
Maximum alignment is achieved when the high-intensity LEDs remain on and the buzzer emits a continuous sound.
Partial or total misalignment is signalled by intermittent flashing of the LEDs and an intermittent acoustic signal from
the buzzer.
Repeat the entire operation for each beam on the barrier.
Note: The constant acoustic signal from the buzzer lasts for a maximum of three minutes. To obtain good alignment,
the RECEIVER optics should perform a FULL rotation on the horizontal axis to SCAN the optical signal.
60