Optical Synchronization - Elkron EL250RT Notice D'installation Et D'utilisation

Colonne d'extérieur à infrarouges actifs - portée 250 m
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.2.4 OPTICAL SYNCHRONIZATION

Set DIP 4 on the 12-position switch to ON and select the transmission channel from 1 to 3 (channel 1 is the default setting)
on the 4-position switch; the selected channel must be the same on the TX board and the RX board.
Note: When using optical synchronization, do not position more than one transmitter in the same line facing in the
same direction.
Note: See below for information and settings for the MES9012 circuit board.
54
RX channel
1
2
3
4
ON
TX channel
1
2
3
4
ON
Set DIP 4 to the ON position
1
2
3
4
5
ON
OPTICAL SYNCHRONIZATION is activated in the
ON position
EL250RT
6
7
8
9
10
11
12

Publicité

Table des Matières
loading

Table des Matières