TROUBLESHOOTING

8.1
DISPLAY DOES NOT ILLUMINATE:
• Check fuses on the circuit boards.
• Check input terminals on board for correct input voltage. Refer to the circuit board diagram.
• Check the flat cable from the circuit board to the display.
8.2
PUMP(S) DOES NOT RUN:
• Check pump(s) output terminals for loose screws and disconnected wires.
• Check for proper voltage across motor windings.
• Check for obstruction in pump head(s).
8.3
TOO MUCH DETERGENT:
• Check the voltage to the system.
• Check for open wires between the probe and the connections to the circuit board barrier.
8.4
TOO LITTLE DETERGENT:
• Check the voltage to the system.
• Check pump operation for proper speed.
8.5
PUMP(S) RUNS TOO SLOWLY:
• Check roller block for binding.
• Check for lubrication on squeeze tube.
8.6
LOSS OF PUMP(S) PRIME:
• Check pickup line for any holes or air leaks.
• Check squeeze tubing in pump for any cracks or pin holes.
• Check tubing for deterioration.