WAREDOSE 35
28c
R on 15s off 120 s
28d
rin qty 20.0 ml
29
rinse delay 15s
0000138112
SET THE DOSING ON/OFF CYCLE OF THE RINSE PUMP
If you choose to control the RINSE PUMP in CYCLIC MODE, this
will be the next parameter to set.
In this mode, the RINSE PUMP will run with a defined ON/OFF
cycle, for the duration of the RINSE signal on the S2 input.
This mode is generally used for Conveyor or Flight type machines.
Press the central button to confirm the shown pair of values.
By using the right/left button, you can first adjust the ON TIME of
the pump, from 1sec to 30sec in steps of 1 second.
The default value is 15sec.
After central button is pressed, by using the right/left button, you
can adjust the second value, setting the OFF TIME of the pump,
from 5sec to 180sec in steps of 5 seconds.
The default value is 120sec.
If the signal on the S2 input disappears while the pump is dosing,
the pump will continue its dosage for the programmed ON TIME
and then the cycle will be paused. If the signal on the S2 input
disappears while the pump is not dosing, that means during its OFF
TIME, the system will remember the part of the OFF TIME already
elapsed and, when the signal on the S2 input returns, will complete
the remaining time of the OFF period , and then will start the ON
TIME.
Once the chosen values are displayed, press the central button to
confirm.
SET THE QUANTITY OF RINSE AID TO BE DOSED
If you choose to control the RINSE PUMP in QUANTITY MODE,
once the parameter has been confirmed at the point 27, this will be
the next parameter to set.
In this mode, the RINSE PUMP will run with a defined speed for a
calculated time, after the detection of the RINSE signal on the S2
input.
The speed and time values are determined by the system in order
to dose the set quantity of chemical based on the calibration value
stored in the memory.
Press the central button to confirm the shown value.
By using the left and right buttons, you can increase or decrease
the quantity to be dosed by the pump, from 0.0 ml to 500.0 ml in
steps of 0.1 ml.
The default value is 5.0 ml.
SET THE DELAY TIME OF THE RINSE PUMP
This parameter defines the delay for the activation of the RINSE
PUMP once a signal is detected on the S2 input, no matter which
mode has been selected for this pump.
Press the central button to confirm the shown value.
By using the left or the right button, you can adjust the value from
1sec to 30sec in steps of 1 second.
The default value is 0sec (no delay).
Once the chosen option is displayed, press the central button to
confirm it.
rev. 1.0
20