Seko WAREDOSE 35 Manuel D'installation page 18

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN
WAREDOSE 35
21d rin qty 20.0 ml
22
rinse delay 15s
5.2 PROGRAMMING OPTIONS IN PROBELESS MODE
If, you selected the PROBELESS MODE at the point 13, the following parameters of the PROGRAMMING section
will be the ones shown in this section
DISPLAY READING
23
det speed 75%
0000138112
SET THE QUANTITY OF RINSE AID TO BE DOSED
If you choose to control the RINSE PUMP in QUANTITY MODE,
once the parameter at the point 20 has been confirmed, this is the
next parameter to set.
In this mode, at the detection of the RINSE signal on the S2 input
the RINSE PUMP will run at its maximum speed for a time
calculated to dose the selected quantity (ml) of chemical.
By using the left and right buttons, you can increase or decrease the
quantity to be dosed by the pump, from 0.0 ml to 500.0 ml in steps
of 0.1 ml.
The default value is 5.0 ml
NOTE: If the pump hasn't been calibrated, the dosing time will be
calculated based on the nominal flow rate; if the pump has been
calibrated, the dosing time will be calculated based on the real flow
rate. In this case, of course, the dosage will be more accurate.
Press the central button to confirm the shown value.
SET THE DELAY TIME OF THE RINSE PUMP
This parameter defines a delay for the activation of the RINSE
PUMP once a signal is detected on the S2 input, no matter which
mode has been selected for this pump.
Press the central button to confirm the shown value.
By using the left or the right button, you can adjust the value from
0sec to 30sec in steps of 1 second.
The default value is 0sec (no delay).
Once the chosen option is displayed, press the central button to
confirm it.
.
DESCRIPTION
SET THE SPEED OF THE DETERGENT PUMP
If you selected the mode as "PROBELESS" at point 13, you will
access this parameter.
Here you set the SPEED OF THE DETERGENT PUMP.
Press the central button to confirm the shown value.
By using the left or the right button, you can adjust the value from
15% to 100% in steps of 5%.
The default value is 75%.
Once the chosen option is displayed, press the central button to
confirm it.
rev. 1.0