Seko WAREDOSE 35 Manuel D'installation page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN
WAREDOSE 35
27
rin mode TIMED
28a
rin speed
28b
rin time 15sec
0000138112
SET THE MODE OF THE RINSE PUMP
Once the previous parameter has been confirmed, you will access
this one. Here you can set how the RINSE PUMP is controlled.
Press the central button to confirm the shown selection.
By using the left or the right button, you can scroll through the four
available options: SPEED, TIMED, CYCLIC or QUANTITY.
In SPEED mode, the RINSE PUMP will run at the selected
speed for the duration of the RINSE signal
In TIMED mode, the RINSE PUMP will run at its maximum
speed for the programmed time once it has detected the
RINSE signal.
In CYCLIC mode, the RINSE PUMP will run indefinitely
with the programmed ON/OFF cycle, for the duration of the
RINSE signal.
In QUANTITY mode, the RINSE pump will runfor the time
needed, according to calibration value, to dose the amount
of chemical product indicated in the following point 28d
The default choice is "SPEED".
Once the chosen option is displayed, press the central button to
confirm it. This selection will change what is the next parameter to
set.
SET THE SPEED OF THE RINSE PUMP
75%
If you choose to control the RINSE PUMP in SPEED MODE, once
the previous parameter has been confirmed, this will be the next
parameter to set.
In this mode, the RINSE PUMP will run for as long as there is a
signal voltage present at the S2 input connector.
Press the central button to confirm the shown value.
Press the left or the right button to adjust the value from 15% to
100% in steps of 5%.
The default value is 50%.
Once the chosen option is displayed, press the central button to
confirm it.
SET THE DOSING TIME OF THE RINSE PUMP
If you choose to control the RINSE PUMP in TIME MODE, this will
be the next parameter to set.
In this mode, the RINSE PUMP will start as soon as a signal is
detected on the S2 input and will then run for the programmed
time.
Press the central button to confirm the shown value.
By using the left or the right button, you can instead adjust the
value from 1sec to 30sec in steps of 1 second.
The default value is 15sec.
Be aware that the pump will continue to dose for the programmed
time even if the signal present on the S2 input disappears. So, set
the run time equal to or less than the rinse cycle duration.
Once the chosen option is displayed, press the central button to
confirm it.
rev. 1.0
19

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières