Programming Procedure; Setup Requirements - Honeywell KaltecSoft Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29

2.3 Programming procedure

1.
Setting the time of day
The first two digits (00) of the display will flash prompting the
installer to set the time.
The time is adjusted by using the [UP], [DOWN] keys.
Pressing the [SET] key enters the hours. The minutes are set
by using the [UP], [DOWN] keys.
Pressing the [SET] key once enters the minutes and moves
the display into the Set Hardness mode. This can be
displayed in PPM, degrees German, or degrees French
depending on the model of softener.
Hardness in °dH
2.
Setting the supply water hardness
The display default is 16 °dH (typical hardness level) which
indicates a setting suitable for the supply water hardness
which has to be measured and entered during the set up of
the softener. Use the [UP] [DOWN] keys to adjust the setting
to match that of the one you obtained / identified with the
water hardness test kit.
MU0H-1420 GE23 R0618
KaltecSoft
Initial display on start up »
TIME «
[UP]
[DOWN]
GB
Pressing the [SET] set key once enters the hardness and
moves the display to Set Recharge Time Mode.
3.
Setting the recharge time
To operate effectively, your water softener needs to
regenerate periodically (dependent on the hardness of the
supply and amount of water used). The default time of day
when this is to occur is 2:00 a.m. To alter this setting use the
[UP] [DOWN] keys.
Pressing the [SET] key once enters the recharge time and
moves the display into service mode.
3
Installation Guidelines

3.1 Setup requirements

National guidelines and regulations:
Observe all applicable installation regulations, general
guidelines, hygiene requirements, and technical
specifications.The hard water to be fed into the unit must
always meet the specifications of the national Drinking Water
Ordinance or EU Directive 98/83/EC. The total dissolved iron
and manganese may not exceed 0.1 mg/l. The hard water to
be fed into the unit must always be free of air bubbles.
Frost protection and ambient temperature:
The installation site must be free of frost and kept free of
chemicals, paint, solvents and fumes.
The ambient temperature should not exceed 40°C, even
before the machine is started.
Please avoid direct heat sources, e.g. radiators and exposure
to sunlight.
5
[SET]
» RECHARGE TONIGHT
TIME «
» SERVICE«