5.3 Maintenance and wearing parts

Wearing parts must also be replaced within the prescribed
maintenance intervals in order to guarantee functionality and
fulfil the warranty conditions. The water softener should be
serviced once a year.
Wearing parts may only be replaced by qualified personnel
(fitters or after-sales service team).
We recommend that you enter into a maintenance agreement
with your fitter or the aftersales service team.
6

Fault finding

6.1 Troubleshooting
Attention:
If your water softener is not performing as it should, please run through the check list below.
Checklist
Problem: Water still remains hard.
Is there a minimum of 150 mm of salt in the brine
cabinet?
Is the power on?
Is the softener online?
Hydraulic problem during regeneration (e.g. pressure
drop of water).
Is the hardness setting correct?
Problem: Water level in brine cabinet reaches overflow.
Is the line pressure within the specification of the water
softener?
Pressure falls outside of the water softener
specification.
Is there flow through the drain line?
Has there been a power interruption?
Problem: No water.
Is the mains stop valve open?
Are the inlet and outlet valves of the water softener
open?
If any overflow situation occurs or if any of the above
requires action reduce the water level and initiate a
regeneration by pressing and holding the manual
regeneration key [RECHARGE] for more than six
seconds.
MU0H-1420 GE23 R0618
GB
Cleaning information:
For cleaning use just clear drinking water! Using different
cleaning solutions (alcohol or alcohol based cleaning agents)
will damage the plastic surfaces of the device.
5.4 Disposal and environmental
information
At the end of product life please contact Customer Services
to arrange a new replacement for your softener.
Disposal of your softener and any electrical parts (e.g. 0.22μF
capacitor battery,5.5 V) should only be carried out at
authorised WEEE recycling centres.
Solution
Fill the brine cabinet with salt.
Switch the power on and check connections.
Close the by-pass valve and open the inlet and outlet
valves.
Please restart the regeneration manually.
Reset the hardness if required.
Connect a pressure gauge to a water outlet and check
the pressure is between: 1.0 - 8.0 bar.
Fit a pressure reducing valve or booster pump as
required.(observe the note below)
Check the drain line is not kinked, blocked or frozen.
Check that the power is on and the connections are
secure.
Open the mains stop valve.
Open the inlet and outlet valves to the water softener.
Attention:
If your water softener is not performing as it should, please
run through the check list below.