Operation; Controls And Display Elements, Main Menu - Conrad FHT 8W Notice D'emploi

Relais de besoin calorifique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

If a switching actuator with switcher relay outlet such as the "FS20 AS1" is to be used, then any given
normal operation switching (contact open or closed when heating demand is present) can be selected
as can any signal loss switching (contact open or closed).
If you select option "2" at "Activate FS20" then the relay of the wireless receiver will operate opposite
to the switching mode of the internal relay.

8. Operation

The menu structure can be seen in chapter 14, the menu language is German.
The numbers in brackets in the following text refer to the menu structure figure in
chapter 14.
As a rule, the device starts in automatic mode (1), as seen in the following example:
"AUT" is shown in the display to indicate automatic mode. At the top, two segments per thermostat
indicate an existing heating demand for thermostats 1, 3, 4 and 8. "An" is German for "On".
a) Controls and display elements, main menu
• The "Menu/Enter" button calls up the main menu (2) The menu items "Manuell/manual" (manual
operation), "Status" (status display), "Anlernen/programme" (programming a thermostat), "Lö-
schen/delete" (deleting a thermostat), "Grenzwerte/limit values" (programming the limit values)
and FS20 (connection to FS20) are available.
• The desired menu item can be selected with the "+" and "-" buttons and confirmed with the
"Menu/Enter" button.
• Pressing the "ESC" button returns you to the automatic mode from any sub-menu.
• The switching state is shown by the device's green LED.
LED on = switching state = on
LED off = switching state = off
34

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

56 00 98

Table des Matières