0.1 - 0.5 s
0.1 - 0.5 s
Fig. 8: Restore measurement range to factory settings
Yellow, in range
Blue, I
out
Green, U
out
Any color
LED flashes (3 Hz)
12 Service data (IO-Link)
Table 2: IO-Link-specific
Index dec (hex) Name
0 (0x00)
Direct parameter 1
1 (0x01)
Direct parameter 2
16 (0x10)
Manufacturer name
17 (0x11)
Manufacturer text
18 (0x12)
Product name
19 (0x13)
Product ID
20 (0x14)
Product text
21 (0x15)
Serial number
22 (0x16)
Hardware version
23 (0x17)
Firmware version
24 (0x18)
Application-specific
name
40 (0x28)
Input process data
1)
ro = read only, rw = read/write
Table 3: System command
Index dec (hex) Name
2 (0x02)
System command
1)
wo = write only
AVENTICS™ SM6-AL | R412017927-BAL-001-AF | English
LED 1
LED 2
8 s
0.1 – 1 s
> 10 s
Format (offset)
Length
Record
16 bytes
Record
16 bytes
String
16 bytes
String
64 bytes
String
16 bytes
String
64 bytes
String
64 bytes
String
8 bytes
String
5 bytes
String
5 bytes
String
16 bytes
PD In
2 bytes
1)
Access
Value Value range
wo
160
Teach_MeasuringRangeS-
tart
161
Teach_MeasuringRangeEnd
162
Reset_MeasuringRange
1)
Access
ro
rw
ro
ro
ro
ro
ro
ro
ro
ro
rw
ro
13