CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to
connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the fixture's chassis ground. Grounding the common can cause a
ground loop, and your fixture may perform erratically. Test cables with an ohm meter to check correct polarity and
to make sure the pins are not grounded or shorted to the shield or each other.
3-PIN TO 5-PIN CONVERSION CHART
Note! If you use a controller with a 5-pin DMX output connector, you will need to use a 5-pin to 3-pin adapter.
The chart below details a proper cable conversion:
Conductor
3 Pin Female (output)
Ground/Shield
Pin 1
Data (-) signal
Pin 2
Data (+) signal
Pin 3
Do not use
Do not use
Setting up a DMX Serial Data Link
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the controller.
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the input
connector of the next fixture consisting of a (male) 3 pin connector.
3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
Functions
[MIC]: Mic for sound mode
[MENU]: press this button to go back to the main menu or to leave
submenus
[DOWN]: press this button to go down in the menu
[UP]: press this button to go up in the menu
[Enter]: press this button to confirm the selected function in the menu
[Display]: shows the information on the different modes and functions
[DMX IN]: 3p XLR Male connector to receive DMX data from a console or
use in Master/slave modes
[DMX OUT]: 3 pin XLR Female connector to connect other projectors or use in Master/slave modes
[POWER IN]: Powercon socket, connect the supplied mains cable here
[POWER OUT]: Powercon connector to power another moving head in Master-slave mode
[FAN]: for cooling the electronic components in the base of the machine
©Copyright LOTRONIC 2017
COMMON
DMX +
INPUT
DMX-
5 Pin Male (Input)
Pin1
Pin 2
Pin 3
Do not use
Do not use
MY340-FXZ
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3
(DMX+) of the last
fixture.
Page 4