Installation and connection (continued)
Supporting rod made of non-magnetizable material
Fig. 4-8:
Example 2, BTL installed with supporting rod
4.4

Electrical Connection

Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tab. 4-2 to Tab. 4-3.
Note the information on shielding and cable
routing on page 11.
4.4.1

Connector S32

Pin
BTL5-S1_ _...-S32
1
+Clk
2
+Data
3
–Clk
4
Not used
1)
5
–Data
6
GND
7
20...28 V
8
Not used
1)
Unassigned leads that are not used can be connected to the GND on
1)
the controller side but not to the shield.
Tab. 4-2:
Connection assignment BTL5...-S32
Fig. 4-9:
Pin assignment of S32 (view from above on BTL), 8-pin
M16 circular plug
10
english
Magnet
(e.g. BTL-P-1028-15R)
4.4.2

Cable connection

Wire color
BTL5-S1_ _...-KA_ _/K_ _/FA_ _/F_ _
YE
Yellow
+Clk
PK
Pink
–Clk
GY
Gray
+Data
GN
Green
–Data
BU
Blue
GND
BN
Brown
20...28 V
WH White
Not used
1)
Unassigned leads that are not used can be connected to the GND on
1)
the controller side but not to the shield.
Tab. 4-3:
Cable assignment BTL5-...-cable