TECHNICAL DATA
MODEL
TYPE
OUTPUT
(1)
FUEL
- Net calorific value
- Absolute density
- Max. delivery
- Pressure at max. delivery
(2)
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE LEVELS
(3)
APPROVAL
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m s.l.m.
(2) Pressure at test point 16)(A)p.8, with zero pressure in the combustion chambre, with open gas ring 2)(B)p.16 an maximum burner output
(2) Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
VARIANTS:
BURNER
RS 70/M
Blast tube lenght mm
250
ACCESSORIES
(optional):
•
KIT FOR LPG OPERATION: The kit allows the RS 70-100-130/M burners to operate on LPG.
BURNER
OUTPUT kW
BLAST TUBE LENGHT mm
CODE
•
OUTPUT POWER REGULATOR KIT: Under modulating operation, the burner automatically adapts to one of an infinite number of firing rates
between the low and high flame output position, thus ensuring stable operating conditions in terms of temperature or pressure. Two components
should be ordered: • Power regulator to install to the burner; • probe to install to the boiler.
PARAMETER TO BE CHECKED
Temperature
Pressure
•
GAS TRAIN ACCORDING TO REGULATION EN 676 (with valves, pressure governor and filter): see page 18.
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.
MAX.
kW
Mcal/h
MIN.
kW
Mcal/h
kWh/Nm
Mcal/Nm
3
kg/Nm
3
Nm
/h
mbar
°C
°C max
V
Hz
rpm
W
V
A
V1 - V2
I1 - I2
W max
dBA
CE
RS 100/M
RS 130/M
385
250
385
280
415
RS 70/M
242 ÷ 814
250
385
3010097
3010098
3010099
Range
- 100...+ 500°C
0...2,5 bar
0...16 bar
RS 70/M
828 T1
465 - 814
400 - 700
135
116
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
G25
10
8,6
3
8,6
7,4
3
0,71
0,78
81
94
10,3
15,2
• On-Off (1 stop min each 24 hours).
This burner is also fitted for the continuos operation, if it is equipped
with the control box LANDIS type LGK 16.333 A27 (interchangeable
with the burner control box Landis LFL 1.333).
• Progressive two-stage or modulating by kit (see ACCESSOIRES).
Boilers: water, steam, diathermic oil
0 - 40
60
230 - 400 with neutral ~ +/-10%
50 - three-phase
2800
1100
220/240 - 380/415
4,8 - 2,8
230 V - 1 x 8 kV
1 A - 20 mA
1400
IP 44
90/396 - 89/336 - 73/23
75
0085AQ0708
COUNTRY
IT-AT-GR-DK-FI-SE
ES-GB-IE-PT
NL
FR
DE
BE
LU
RS 100/M
RS 130/M
349 ÷ 1163
466 ÷ 1512
250
385
280
3010100
3010101
PROBE
Type
Code
PT 100
3010110
Output probe
3010213
4...20 mA
3010214
6
RS 100/M
RS 130/M
829 T1
698 - 1163
930 - 1512
600 - 1000
800 - 1300
150
129
G20
G25
G20
10
8,6
10
8,6
7,4
8,6
0,71
0,78
0,71
116
135
151
9,3
13,7
8,6
2800
1500
220/240 - 380/415
220/240 - 380/415
5,9 - 3,4
1800
77
CATEGORY
II
2H3B/P
II
2H3P
II
2L3B/P
II
2Er3P
II
2ELL3B/P
I
I
2E(R)B,
3P
II
2E3B/P
415
3010102
POWER REGULATOR
Type
RWF40
GB
830 T1
160
138
G25
8,6
7,4
0,78
175
12,7
2800
2200
8,8 - 5,1
2600
78,5
Code
3010212