Water Supply And Drain Connections - Hoshizaki IM-240DNE Notice D'installation

Masquer les pouces Voir aussi pour IM-240DNE:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
ENGLISH

9. WATER SUPPLY AND DRAIN CONNECTIONS

* The connections to the mains water supply must be made in accordance with the countries' current requirements of the Water
Supply or Water Fittings Regulations.
* Icemaking water must be potable water. Where scaling can be caused by water quality:
- Installation of an external filter or softener is recommended. Contact your local water treatment professional or Hoshizaki
service agent.
- Change to the "full drain flush" mode is recommended. Contact your local Hoshizaki service agent.
* Water supply pressure should be minimum 0.07 MPa (0.7 bar) and maximum 0.8 MPa (8 bar). If the pressure exceeds 0.8 MPa (8
bar), use a proper pressure reducing valve. Do NOT throttle back the supply tap.
* A plumbing permit and services of a licensed plumber may be required in some areas.
* The icemaker drain is gravity flow, so ensure drain hose has an adequate pitch or fall.
* Drain lines should not be installed directly to the sewer system. A vertical air gap of a minimum of 5
cm should be between the end of the drain hoses from the icemaker and storage bin and the floor
drain.
* Prevent a backflow into the storage bin.
* On water-cooled model, a back flow preventer may be required in the cooling water circuit.
* Be sure to use the new hose-sets supplied with the appliance. Do not reuse any old hose-sets.
[Air-Cooled Model]
1) Attach the angled end of flexible inlet hose (accessory) to the
G3/4 fitting on the rear of the icemaker as indicated, ensuring
rubber sealing washer is correctly positioned. Hand tighten
sufficiently to provide leak free joint.
2) Attach the other end of inlet hose to the water tap, noting washer
is correctly positioned before hand tightening as above. It is a
wise precaution to have a stop valve within easy reach.
3) Hand tighten grey flexible outlet hose (accessory) onto the R3/4
fitting on the rear of the icemaker as indicated, ensuring rubber
washer is correctly positioned to obtain a leak free joint. The
hose can be cut to length as necessary to suit position of main
drain.
[Water-Cooled Model]
* Hoshizaki recommends that the water-cooled condenser should
be connected to a closed circuit recirculating type cooling system
utilizing a tower, water chiller or similar. Water make up should be via a ball valve/break tank
arrangement.
* Whilst connecting a water-cooled condenser to a mains water (potable) supply will not affect
the performance of the machine, it will most certainly cause a high use/waste of a valuable
resource and is not recommended.
* The services of a licensed or coded plumber should be used to ensure a correct installation.
* The connections should be made properly in compliance with the applicable national or local regulations.
WARNING
Connect to potable cold water supply only.
10
Air-Cooled Model
Inlet Hose
Outlet Hose
5cm air gap
Floor
Drain
Water Supply Inlet G3/4
Drain Outlet R3/4
Water Supply Tap
Inlet Hose

Publicité

Table des Matières
loading

Table des Matières