3
Technical data
Rated data
Rated data
Output power 400 V mains
Data for operation with upstream power supply
module on mains voltage
DC−bus voltage
DC−bus current
Rated output current at 4 kHz
(causes a heatsink temperature of 70°C at an
ambient temperature of 20°C)
Rated output current at 8 kHz (at an ambient
temperature of 20°C it causes a heatsink
1)
temperature of 70°C)
Max. output current
(acceleration current)
Continuous current at standstill
(holding current at 90°C, 4 kHz)
Short−time standstill current
(holding current at 90 °C, 4 kHz)
Short−time standstill current
(holding current at 70 °C, 4 kHz)
Short−time standstill current
(holding current at 70 °C, 8 kHz)
Power loss (operation with
rated current at 4 kHz / 8 kHz)
Max. output frequency
Mass
1)
If the heatsink temperature reaches 70°C, the switching frequency automatically changes to
4 kHz.
2)
The indicated temperature is the measured heatsink temperature (C0061).
L
Application software:
94
Type
S
[kVA]
rated
U
mains
V
DC−bus
I
DC−bus
I
[A]
r
I
[A]
r
I
max
2)
I
0,eff 4 kHz
I
0,eff 4 kHz
2)
I
0,eff 4 kHz
2)
I
0,eff 8 kHz
2)
Total
Inside the
P
[W]
loss
device
Heatsink
f
[Hz]
out
m [kg]
S = Speed & Torque
M = Motion
l
Axis module
ECSxL032
8.3
[V]
400
480
400
[V]
[A]
15.6
12.5
20.9
12.7
10.2
17.0
8.5
6.8
11.3
[A]
32.0
[A]
16.0
12.8
23.0
[A]
18.1
[A]
24.0
[A]
12.1
144.5
27.5
117.0
approx. 2.4
P = Posi & Shaft
A = Application
ECSxL048
ECSxL064
11.2
13.2
480
400
480
15 ... 770
16.8
24.5
19.6
13.6
20.0
16.0
9.0
13.3
10.6
48.0
64.0
18.4
27.0
21.6
27.2
36.3
36.0
48.0
18.1
24.2
166.5
199.0
34.5
41.0
132.0
158.0
600
approx. 3.3
EDKCSDX064 DE/EN/FR 3.0