Lenze ECSDS Série Instructions De Montage page 119

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Analog input configuration
Use C0034 to set whether the input is to be used for a master voltage
ƒ
(±10 V) or a master current (+4 ... 20 mA or ±20 mA).
Set jumper bar X3 according to the setting in C0034:
ƒ
(
Stop!
Do not plug the jumper on the pins 3−4! The axis module cannot be
initialised like this.
Jumper bar X3
5
3
1
5
3
1
EDKCSDX064 DE/EN/FR 3.0
Setting
6
5−6 open
4
Jumper on 1−2: Parking
position
2
6
4
5−6 closed
2
l
Electrical installation
Control terminals
Analog input
Measuring range
C0034 = 0 (master voltage)
l
Level: −10 ... +10 V
Resolution: 5 mV (11 bits + sign)
l
Scaling: ±10 V º ±16384 º ±100 %
l
C0034 = 1 (master current)
l
Level: +4 ... +20 mA
Resolution: 20 mA (10 bits without
l
sign)
Scaling:
l
+4 mA º 0 º 0 %
+20 mA º 16384 º 100 %
C0034 = 2 (master current)
Level: −20 ... +20 mA
l
Resolution: 20 mA (10 bits + sign)
l
Scaling:
l
±20 mA º ±16384 º ±100 %
5
119

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ecsdp sérieEcsdm sérieEcsda sérieEcs

Table des Matières