5.3.7 CLOSING THE FIRING CHAMBER DOOR / G ASKET: DURING CONTROLLED LIVING
SPACE VENTILATION / OPERATIONS INDEPENDENT OF INDOOR AIR
Always make sure that the firin
chamber door closes properly and
that the door gasket is undamaged
and intact!
THE PRESSURE IN THE IN STALLATION ROOM
5.3.
8
The supplier of the ventilation system
must ensure that the pressure does
not exceed 4 Pa.
6. FIRING THE STOVE
6.1. DUO Module – GREATER DIRECT HEAT EMISSION (OPTIONAL)
When you wish greater direct heat
emission during the heating up and
burning down phases, simply open
the convection module all or part
of the way after igniting the charge.
To open, push the lever (A) back to
the stop until the desired position is
reached (max 45°). When you wish to
raise the proportion of radiated heat,
close the Duo Module all or part of
the way by pushing the lever back
to its initial position. When you want
!
A defect door gasket can cause flue gas to leak into the liv
ing space and jeopardise health.
!
The pressure in the installation room
may not exceed 4 Pa.
Set aside enough firewood, firelighters, kindling, and matches. Now open the
firing chamber door. Holding the door open with one hand, place the firewood in
the combustion chamber so that it leans slightly backwards. The first row of
firewood should touch the rear wall of the combustion chamber. Now add the
remaining firewood so that there is a gap of about 2 cm from the side walls of the
combustion chamber. The front ash shield may not be covered with wood. We
recommend charging the stove with about 1 kg or about six pieces of firewood 33
cm long. The oven can be filled in up to 4 partial amounts.
Now ignite the firelighter.
Release the firing chamber door.
The firing chamber door closes and locks automatically.
The wood burns from top to bottom.
The firewood burns for up to two hours.
When the firewood has burned down and there are only embers left in the
firing chamber, this is how you close the ventilation valve by pressing
the manual ventilation adjusting device. If the ventilation valve does not close
manually, it closes automatically after the fire is extinguished.
IMPORTANT!
Do not open the door to the combustion chamber while the fi e is still burning and
the embers are still hot.
to utilise direct heat emission while you are emptying the storage heating stove,
simply leave the convection module closed. Bear in mind that direct heat emission
reduces the heat storage capacity and causes your storage heating stove to cool
down faster.
A
DUO Module
DUO Module
closed
A
!
A
open
The flow of hot air heats
the convection module.
Please use the glove when
operating the stove.