4.2 SAFETY DISTANCES TO FIXED TONWERK STORAGE
HEATING STOVES: T-LINE eco2 T-NEO eco2
Safety distance A
The side and rear panels must be no closer
than 10 cm to flammabl materials
Safety distance B
Smoke pipes must be no closer than 20 cm
to flammabl materials
Safety distance C + D
Flammable floo materials must be
no closer than 50 cm to the front and
30 cm to the sides
Safety distance E
Firing chamber apertures must be no
closer than 80 cm to flammabl mate-
rials within the radiation zone
Safety distance F
The minimum distance from the ceiling
is 50 cm
4.3 SAFETY DISTANCES TO SWIVELLING TONWERK STORAGE
HEATING STOVES: T-LINE eco2 T-NEO eco2
Safety distance A
The side and rear panels must be no closer
than 10 cm to flammabl materials
Safety distance B
Smoke pipes must be no closer than 20 cm
to flammabl materials
Safety distance C+D
The distance over the whole swivelling
angle must be no less than 50 cm
Safety distance E
A minimum distance of 80 cm applies to
the whole swivelling range
Safety distance F
The minimum distance from the ceiling
is 50 cm
4.4 GENERAL SAFETY
INSTRUCTIONS
• Never leave children alone or unat-
tended at a burning fi eplace.
• Teach your children how to behave
properly and operate safely the fi e-
place.
• Every stove gets hot when fi ed: risk
of burning!
• Avoid touching the outside surfaces
when the stove is operating.
• Do not burn refuse or painted wood.
• Dispose of the ashes only after they
have cooled completely.
• Inform your specialised dealer with-
out delay of defect gaskets.
• Observe the information in our op-
erating instructions and make a
proactive contribution to fi e pre-
vention and the protection of our
environment.
4.5 CHIMNEY SAFETY
INSTRUCTIONS
The required chimney flue shall be
13 Pa. If the height and cross-section of
the chimney cannot be adapted to
meet the requirements, this may
result in wind-related problems and
consequently dis-rupted combustion,
as well as formation of condensation.
If the chimney flu is too high, draught
stabilisers shall be installed. Local
and national regulati-ons must be
complied with.
If the chimney catches fire,
immediately call the fire brigade.
4.6 CONDUCT DURING
MALFUNCTIONS –
SHUTTING DOWN
SAFELY
In rare cases, also a pilot fire can fail
to generate a draught in the flue
You must then ask your chimney
sweep for advice. On no account must
you attempt to light a larger fi e. When
smoke escapes from your stove, air
the room immediately and contact
your chimney sweep. You should then
refrain from firin your stove.