HLT 2100 / HLT 2500 SSI
7.2 HLT 2500 – L2
Input data
Measuring ranges
Design
Housing
Output data
Output signal
Resolution
Non linearity
Hysteresis
Repeatability
Temperature coefficient
Sampling rate
Environmental conditions
Operating temperature range
Storage temperature range
- mark
Vibration resistance acc. to
DIN EN 60068-2-6 at 50 .. 2000 Hz
Shock resistance acc. to
DIN EN 60068-2-27 (11 ms / half sine)
Protection class acc. to DIN EN 60529
Installation
Relevant data for SSI
SSI clock input
SSI data output
SSI clock frequency
SSI mono time, typical
Other data
Supply voltage
Residual ripple of supply voltage
Current consumption without output
Weight
Note: Reverse polarity protection of the supply voltage and excess voltage protection and short
circuit protection are provided.
FS (Full Scale) = relative to complete measuring range
1)
with mounted mating connector in corresponding protection class
Edition: 2017-08-31
50 .. 4000 mm
Profile design, with magnetic guidance,
joint on top
Measuring body: aluminium
SSI
0.001 mm
± 0.1 mm
± 0.15 mm
mm)
0.02 mm
0.1 mm
mm)
0.005 mm -
≤
± 0.0015 % FS / °C
≤
Depending on length
0 .. +70 °C, optionally – 20 ..+ 70 °C
-30 .. +85°C
EN 61000-6-1 / 2 / 3 / 4
10 g
≤
100 g
≤
1)
IP 65
No restrictions
Opto coupler
RS-422, 2 wires
95 .. 1000 kHz
20 µs
24 V DC - 20.. + 10 %
≤ 250 mV
PP
< 250 mA
Depending on length:
HYDAC ELECTRONIC GMBH
(measuring range
(measuring range > 1500
(measuring range
(measuring range > 1500
0.05 mm (depends on length)
≤
1 m
≤
1.5 m
≤
2 m
≤
> 2 m
50 mm:
4000 mm:
17
1500 mm)
≤
E
1500 mm)
≤
0.5 ms
0.75 ms
1.0 ms
1.5 ms
̴ 450 g
̴ 4150 g
Part No.: 669999