AVENTICS | EV03 | R414008223–BAL–001–AA | English
Table 4:
Meaning of the material short key
Placeholder Meaning
EV03
Series
000
Min. output pressure
YYY
Max. output pressure
ZZZ
Set point
1)
QQQQ
Version
Display
Defined failure
response to a lack
of UA power supply
to the valves
Output signal
1) Example : CL1P: C = Classic, L = LED, 1 = pressure in the operating line is maintained briefly,
P = actual output pressure value
EV03 pressure regulator versions
EV03 pressure regulators are available in versions with or without display
17
Fig. 3:
EV03 pressure regulators with display (17) and without display (18)
6 Operating Mode
Make sure that the operating pressure lies at least 1 bar above the
maximum output pressure to be controlled. Otherwise, only a reduced output
pressure range is available.
EV03 pressure regulator with base plate
EV03 pressure regulators are always used together with a base plate. The base plate
is supplied with operating pressure from the line connected to supply connection 1
and distributes the volume flow as follows:
W
The EV03 pressure regulator takes as much supply air as necessary to control
the specified set point.
W
The controlled pressure is forwarded to the consumer connected to the base
plate via the base plate's working connection.
Response to power failure
The response to a power failure depends on how the EV03 pressure regulator was
configured on delivery. In the event of a power failure, the device either exhausts the
operating line or briefly maintains the output pressure, depending on the
configuration.
O Refer to the section "Product identification" in chapter 5 for information on how
your device responds to a power failure.
Abbreviation (examples)
EV03 = EV03 series
000 = 0 bar
060 = 6 bar
100 = 10 bar
010 = 0–10 V
020 = 0–20 mA
420 = 4–20 mA
IOL = IO-Link
C = Classic (not for IO-Link)
S = Smart
L = LED
D = display with integrated LEDs
0 = operating line is exhausted via the EV03
1 = pressure in the operating line
is maintained briefly
P = actual output pressure value
S = switch output
C = 10 V constant
18
7 Assembly
Hazardous movements due to incorrect fastening!
Other system parts may be damaged by uncontrolled device movements.
O Make sure that the device is securely fastened.
O Always mount the base plate of the EV03 pressure regulator
– with screws in the through holes or
– with mounting kits to a rail or a mounting plate (see online catalog at
www.aventics.com/pneumatics-catalog)..
You can assemble the EV03 pressure regulator in four different ways:
1. To a mounting plate using screws in the upper through holes,
2. To a mounting plate using screws in the through holes on the side,
3. Using the mounting kit for assembly on a mounting plate (R414002582),
4. Using the rail mounting kit for TH35-7.5 rails (R414002583).
Before assembly
O Make sure the relevant system part is not under voltage or pressure.
O Let the EV03 pressure regulator acclimate itself for several hours before
installation, otherwise water may condense in the housing.
O See the dimensioned drawing for the hole spacing (see Fig. 4).
82
18
34
46
12
Fig. 4:
Dimensioned drawing
NOTICE
12
26.6
14