Brief Description Of The Press Device - NovoPress Comfort-Line ACO202 Manuel D'utilisation

Masquer les pouces Voir aussi pour Comfort-Line ACO202:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
ACO202/ECO202
6

Brief description of the press device

EN
6.1
Automatic press cycle (Fig. 1)
The device features an automatic press cycle. This ensures that the pressing operation is
always completed. For safety reasons, the automatic press cycle only switches on when the
pressing operation has started, i.e. when the fitting starts to be shaped. After the automatic
press cycle has been triggered, the green LED (2) goes out and the pressing operation runs
automatically. The pressing operation can then only be stopped by pressing and holding release
button (4). After the pressing operation has been completed, the motor automatically switches
off and the green LED lights up again.
If start button (1) is released before the automatic press cycle begins, the piston in the press
device moves back to its starting position. The pressing operation will not have been completed.
The pressing operation must be triggered again.
6.2
Release button (Fig. 1)
The pressing operation can be stopped at any time by pressing and holding release button (4).
The piston in the press device then returns to its starting position.
6.3
Rechargeable battery (ACO202 only)
6.3.1
Removing the battery (Fig. 2)
Push in (1) the two release buttons (A) and then remove the battery (2).
6.3.2
Inserting the battery (Fig. 3)
Slide the battery onto the device as illustrated until it clicks into place.
6.3.3
Battery charge indicator (Fig. 2)
The battery charge is displayed when button (B) is pressed. The number of LEDs lit up denotes
the battery charge. One flashing LED indicates a maximum power reserve of 10%. The battery
must be charged soon.
If the battery is inserted in the press device while the battery charge is being checked, the last
pressing operation must have been completed at least 1 minute prior to this. Otherwise the
display will be inaccurate.
6.4
ACO202 and battery
Feature of the press device after extended periods out of use or when changing the
battery:
If the press device is out of use for approx. 30 minutes or the battery is reinserted, it switches to
SLEEP mode. The LED is no longer illuminated. Press the start button briefly to start the press
device.
Information!
The ACO202 press device must only be operated with 18 V lithium-ion
rechargeable batteries. The 18 V rechargeable battery must only be used
in the appropriate press devices.
18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Comfort-line eco202Aco202Eco202Aco203

Table des Matières