fig. 21 control panel - daily programming
You can set two operating time slots according to tab. 7,
where the OFF setting tells the clock to ignore the command:
Selection
START 1
STOP 1
START 2
STOP 2
tab. 7 operating time slots setting
4.5.2
WEEKLY PROGRAMMING
To enable/disable and set the weekly chronothermostat func-
tions. Access via the menu: Set chrono -> weekly program ->
See item chap. 4.3
fig. 22 control panel - weekly programming
The weekly programmer is provided with 4 independent pro-
grams, whose final effect is the combination of the 4 single
programs. The weekly programmer can be activated or deac-
tivated. Moreover, by setting OFF in the time field, the clock
will ignore the corresponding command.
Program with care, avoiding any activation or
deactivation time overlap in the same day in
different programs.
EN
Selection
START PROG 1
STOP PROG 1
MONDAY PROG 1
TUESDAY PROG 1
WEDNESDAY PROG 1
THURSDAY PROG 1
FRIDAY PROG 1
SATURDAY PROG 1
SUNDAY PROG 1
tab. 6 fan adjustment
Another 3 weekly programming levels are avail-
able.
4.5.3
WEEKEND PROGRAMMING
To enable/disable and set weekend chronothermostat func-
tions (days 5 and 6, i.e. Saturday and Sunday).
44
Description
Possible values
activation time
time - OFF
deactivation time
time - OFF
activation time
time - OFF
deactivation time
time - OFF
Program 1
Description
Settable status
Activation time
Time - off
Deactivation time
On/off
translated from the original text
fig. 23 control panel - weekend programming
• To prevent misunderstandings and unwant-
ed start-up or switch-off, activate only one
program at a time if you are not sure of what
you want to obtain.
•
Deactivate the daily program if you want to use the
weekly program.
•
Always keep the weekend program deactivated when
using weekly programs 1, 2, 3 and 4.
•
Activate the weekend program only upon deactivat-
ing the weekly one.
4.6
LANGUAGE SELECTION
This allows you to select the dialogue language among those
available. To modify the language, go to the menu 03 - Choose
language, using the keys (1) and (2) fig. 18a to scroll the items
until you reach the desired language.
fig. 24 control panel - language selection
4.7
STANDBY MODE
Activates the "STAND-BY" mode which switches off the stove
after the room temperature has remained higher than the set
value beyond the default time. When the stove switches off in
this condition, it can only switch back on when the set tem-
perature is lower than the room temperature for a determined
amount of time. To modify the mode, go to the menu 04-
Standby mode, and use the keys (1) and (2) fig. 18a to acti-
vate it/deactivate it.
This function is to be set with the technician dur-
ing first ignition.
4.8
BUZZER MODE
When set at "OFF" the acoustic signal is disabled. To modify
the mode, go to the menu 05 - Buzzer, and use the keys (1)
and (2) fig. 18a to activate it/deactivate it.
4.9
INITIAL LOAD
Perform the operation below when the pellet
loading pipe is empty.
This allows you to perform a pellet preload lasting 90" with
the stove off and cold. Start by pressing the key (1) and inter-
rupt by pressing the key (4). The following also appear on the
display: Timer (A), Power (B), Room Temp. (C).
Instructions for use