First ignition
avoid burns.
Remove the product from the brazier and all components
from the glass which could burn (instruction manual, vari-
ous stickers and any polystyrene). Check that the brazier is
positioned correctly and rests properly on its base.
First ignition could fail as the auger is empty and
is not always able to fill the brazier with the neces-
sary amount of pellets on time for a regular start.
Cancel the failed ignition alarm by keeping the ON/OFF key
pressed for a few seconds. Remove the pellets left in the
brazier and repeat ignition. (see par. "Troubleshooting").
If after several ignition attempts the flame has not yet ap-
peared despite a regular pellet supply, check that the bra-
zier is housed properly. It must fit perfectly in its seat and
be clear of any ash buildup. If this check finds nothing
abnormal, it means there could be a problem linked to the
product components or attributable to incorrect installa-
tion.
In this case, REMOVE THE PELLETS FROM THE
BRAZIER AND REQUEST THE INTERVENTION
OF AN AUTHORISED TECHNICIAN.
Do not touch the stove during the first ignition
as the paint hardens in this phase.
IT is good practice to guarantee efficient ven-
tilation of the environment during the first ig-
nition as the product issues some smoke and
the smell of paint.
Do not remain near the boiler and, as said above, ventilate
the environment. The smoke and smell of paint will dis-
appear after about an hour of operation. Remember that
they are not harmful to health.
The boiler is subject to expansion and contraction during
ignition and cooling phases and therefore you could hear
some slight creeks.
This is absolutely normal as the structure is built in lami-
nated steel and must not be considered a defect.
IT is extremely important to make sure not to overheat the
product immediately, but to bring it to operating temper-
ature gradually by initially using low-power outputs.
This will prevent from damaging the ceramic tiles, welds
and steel structure.
DO NOT LOOK FOR HEATING PERFORMANCE IM-
MEDIATELY!!!
Do not perform any unauthorised change to the appli-
ance.
Use only the original spare parts recommended by the
manufacturerInstructions for use
Mod. CRONOS rev 01
4
INSTRUCTIONS FOR
USE
4.1

PREAMBLE

The product unites the heat of the fire with the
convenience of automatic temperature manage-
ment, ignition and switch off, with the possibil-
ity of programming it for several days. Automatic
loading and the large capacity of the tank provide
greater autonomy and enhanced management of the pellet
boiler. The product must always operate with the door abso-
lutely closed. IT IS essential for the exhaust system to be air-
tight. The product must always be clean to guarantee efficient
performance and correct operation.
4.2

CONTROL PANEL

The control panel displays information regarding the operat-
ing status of the product. Accessing the menu, you can obtain
various types of display and perform the settings available de-
pending on the access level. The displayed information has
different meanings, according to the operating mode and its
position. Figure I4 shows an example of the product off or on.
translated from the original text
fig. 17 control panel off
EN
41

Publicité

Table des Matières
loading

Table des Matières