Unpacking And Inspection; Features - Amprobe ACD-50NAV Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1.800.544.2843
Measurement category:
V : Category III 1000 Volts AC & DC, and Category IV 600 Volts AC & DC.
A : Category III 1000 Volts AC & DC, and Category IV 600 Volts AC & DC.
Per IEC 61010-1 3rd Ed. Measurement Category
Measurement Category IV (CAT IV) is for measurements performed at the
source of the low-voltage installation. Examples are electricity meters and
measurements on primary overcurrent protection devices and ripple control
units.
Measurement Category III (CAT III) is for measurements performed in
the building installation. Examples are measurements on distribution
boards, circuit- breakers, wiring, including cables, bus-bars, junction
boxes, switches, socket-outlets in the fixed installation, and equipment for
industrial use and some other equipment, for example, stationary motors
with permanent connection to the fixed installation.
WARNING
To reduce the risk of fire or electric shock, do not expose this product to
rain or moisture. To avoid electrical shock hazard, observe the proper
safety precautions when working with voltages above 60 VDC or 30 VAC
rms. These voltage levels pose a potential shock hazard to the user. Do not
touch test lead tips or the circuit being tested while power is applied to the
circuit being measured. Keep your fingers behind the finger guards of the
test leads during measurement. Inspect test leads, connectors,
and probes for damaged insulation or exposed metal before using the
instrument. If any defects are found, replace them immediately. Only use
the accompanied test leads, or replace with the same rating or better.

UNPACKING AND INSPECTION

Your shipping carton should include:
1 Power clamp meter
1 Test leads (1 pair)
1 Temp. adapter and probe (for ACD-51NAV and ACDC-54NAV only)
1 Users Manual
1 Carrying case
1 9V alkaline battery (installed)
If any of the items are damaged or missing, return the complete package to
the place of purchase for an exchange.

FEATURES

• True RMS
• Measurements:
o Voltage up to 1000V AC/DC, Resistance, Frequency, THD (Total
Harmonics Distortion) and Individual Harmonics 1 to 25, Power,
Power Factor
o AC Current
- Up to 600A (ACD-50NAV, ACD-51NAV, ACDC-52NAV)
- Up to 1000A (ACD-53NAV, ACDC-54NAV)
www.calcert.com
15
10
20
5
25
0
30
2
sales@calcert.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Acd-51navAcdc-52navAcd-53navAcdc-54navAcd-52nav

Table des Matières