Safety rules
•
The personnel carrying out the installation, commis-
sioning, maintenance or repair of the device must be
properly qualified for this type of work. In particular,
the persons concerned must
- be suitably trained and familiar with handling
compressed-air systems besides being informed
about the associated dangers,
- know the content of the relevant instructions for
installation and operation, and
- prossess vocational qualifications or entitlements
in this particular field of work.
•
Before the start of any work, the housing must first
be depressurized.
•
In the case of CLEARPOINT
MAT®
all the rules of the separate instructions need
®
to be complied with.
•
To ensure safe functioning, only use the device within
the operational limits (operating pressure, operating
temperature, volumetric flow, material stability).
•
Where a BEKOMAT®
that the device is designed for the stated volumetric
flow of compressed air or gas. Condensate surges
into the device can impair the function.
•
In the event of leaks, shut off the compressed-air
supply immediately and eliminate the cause in order
to maintain safe and cost-effective operation.
•
CLEARPOINT
filters, including accessories, must
®
be checked once a week. This applies in particular
to the function of the separator.
CLEARPOINT S040 - M032
filters with BEKO-
®
is installed, it must be ensured
®
english
Areas of application
CLEARPOINT
filters are designed for the separation
®
of solid particles, aerosols, oil vapours and odours from
non-aggressive compressed air or industrial gases. De-
pending on the specific application, the filter housings
are provided with different inserts:
CX Coarse filter for the separation of coarse solid matter
pollutants up to 25 µm.
FX Fine filter element for the separation of liquids up to
0.05 mg/m³ and solid particles up to 1 µm.
SX Super fine filter element for the separation of liquids
up to 0.005 mg/m³ and solid particles up to 0.01 µm.
A Activated carbon filter elements for the separation
of oil vapours up to 0.003 mg/m³ and odours .
R(x) Dust filter for the separation of solid particles,
fineness from C to S
Max. operating pressure:
Max. operating temperature:
Recommended operating temperature:
to 16 bar
+2 °C to +60 °C
C, F, S: +2 °C ... +40 °C
A: +2 °C ... +30 °C
R(x): +2 °C ... +60 °C
7