Decommissioning and Disposal
8
Decommissioning and Disposal
CAUTION! Risk of injury!
Never remove a flow switch or its body from a system under pressure.
+p
Make sure that the plant is shut down professionally.
Before disassembly:
Prior to disassembly, ensure that
the equipment is switched off and is in a safe and de-energised state.
the equipment is depressurised and has cooled down.
Disassembly:
Remove the electrical connectors.
Remove the VH... / VK... using suitable tools.
Disposal:
NO HOUSEHOLD WASTE!
The VH... / VK... consists of various different materials ( § 3). It must not be disposed of
with household waste.
Take the VH... / VK... to your local recycling plant
or
send the VH... / VK... back to your supplier or to
SIKA.
- 36 -
© SIKA • Ea3000_FlowSwitch • 02/2014
VH... / VK...