Quick Operation Guide
4. USAGE INSTRUCTIONS.
4.1 - Place the lift on a firm, flat surface in the
area it is to be used supported its transport
wheels (T).
4.2 - Remove the outriggers from their transport
supports (S) and fully insert them into their
positions (V) checking that they are fixed by
the pins (R).
4.3 - Adjust the outrigger stabilisers (Q) by
turning the cranks to level the lift. Ensure it is
in a vertical position by using the bubble level
indicator (F) found on the base section. The
bubble should be in the centre of the circle.
4.4 - Place the forklifts in a horizontal position
and secure them with the pins.
VMB recommends the SU-070 Elevation Kit
and the BS-070 Elevation Kit which have both
been especially designed for loading and
elevating with the TL-054, TL-055, TL-056.
4.5 - DO NOT OVERLOAD THE LIFT
TL-054 MAXIMUM LOAD IS 220 KG.
TL-055 MAXIMUM LOAD IS 220 KG.
TL-056 MAXIMUM LOAD IS 200 KG.
The lift should NEVER be overloaded. Safety
at work is the most important element. Place
the load onto the lift using an adequate support
according to the need, use so that the weight of
the load will only elevate in a vertical direction.
4.6 - How to place the load
Always load as close to the tower as possi-
ble. The maximum load diminishes according
to the distance from the body of the tower as
illustrated in the diagram below.
VMB ESPAÑOLA, S.A.
ENGLISH
Distance from the
center of the load to
the carriage
A
25 cm
B
30 cm
C
40 cm
D
50 cm
E
60 cm
v7.03 - Depósito legal y Copyright 2007. Todos los derechos reservados.
Maximum load
TL-054/55
TL-056
220 Kg
200 Kg
198 Kg
180 Kg
165 Kg
150 Kg
141 Kg
128 Kg
123 Kg
112 Kg