Automatic rinsing system
The purpose of the rinsing system is to let the resid-
ual water out of the tank at regular intervals and to
let in fresh water . The rinsing system can be started
manually via the remote control unit by means of the
„Flush" button or alternatively via Menu point 31, with
automatic flushing intervals between 1 and 7 days .
For making the setting please refer to the section on
„Menu programming .
An automatic rinsing system is only possible in combi-
nation with the automatic water supply . There is then
no need for any manual water exchange . The connec-
tion of the rinsing system to the local waste-water
mains must be made by a specialist technician, i .e . a
licensed installation technician .
When the waste-water hose is being connected it is
important to make sure that it is not laid in an up-
ward slope and that its length does not exceed 1 .5
metres because the pump's capacity is not limitless
and otherwise no pressure would be built up . It might
therefore be necessary to fill the hose with water be-
foreconnecting it so that a siphon can be created .
EN
Activated charcoal cleaning filters
The two cleaning filters can be easily removed from
the clips . The service life is approx . 6 months which
primarily depends on the dirt in the room air (e .g .
smoke and dust accumulation) .
Air scoop with flexible hose
These accessories are especially used in church or-
gans . The scoop is fitted or screwed to the outlet of
the B 500 . Provided with a flexible aluminium ventila-
tion hose (150 mm), which carries the humidified air
into the critical organ area . The hygrostat must also
be positioned in this area . The hygrostat controls the
B 500 humidifier located on the outside in a position
with good access .
(Wall mounting on brackets is also possible)
UV-technology with Calcium Conversion Cartridge
The low pressure mercury vapour lamp used in the
device operates in the UV-C range in which the wave-
length kills most microorganisms . The humidifier
water is therefore effectively disinfected and is fed
into the water circuit of the humidifier with reduced
germ content . Permanent magnets produce a mag-
netic field, past which the humidifier water is fed .
As a result, the molecular structure of the calcium is
changed so that it can no longer collect on surfaces
in the device . Always keep the passage in the calcium
conversion cartridge clean . (see page B17)
Using softened water can lead to heavy
m
damage to the lime transformation car-
tridge. It's strongly recommended to avoid
the combined usage!
Operating Manual – Electronic Humidifier
B - 11