Changing UV-tubes
1 . Please first remove the switch panel as described
on page 5 . The UV-tube is located under the switch
panel, next to the pump motor .
2 . Pull out the UV-tube on the connecting cable and
replace the tube .
3 . Reattach the electrical connecting head to the UV-
tube properly and insert it into the glass tube again
with care .
The UV-lamp is to be disposed of in accordance with
legal requirements .
The UV-tube has an operating life of about 5000
hours .
m Please take care that the quartz glass body
in which the source sits is not damaged
when fitting and removing the UV-source.
All accessories can be retrofitted at any time at the
factory or by an authorised dealer .