paying attention to the condition of the seal
After the engine is started, turn on the choke throttle gradually and withdraw the throttle switch.
Leave the engine running for 1-2 minutes at low speed to heat the engine.
4.6- Stopping the engine
Please withdraw the throttle switch and leave the engine running for 1~2 minutes at low speed to
cool the engine.
1. Close the Throttle Lever (slow) and leave the
engine running for 1-2 minutes to cool it down.
3. Turn the Engine Switch to "OFF" position.
4.7- Adjusting the idle speed of the engine
The idle speed of the engine was adjusted in the factory
The user should not attempt to adjust it to avoid any danger.
After the throttle lead is completely released, if the idling speed of the engine is too low or too high,
please contact the qualified service person to adjust it.
4.8- After use
Remove the hose, drain off the water inside the pump and remove the water and impurity substances
inside the hose. Store it in the specified place.
Important! In cold winter, please be sure to drain off the water inside the pump after use. As the
temperature outdoors is below zero centigrade, the water inside the pump will be frozen, which may
damage the pump.
2. Close Fuel Valve Lever to "OFF" position
In case of emergency:
Please stop the engine immediately
Turn off the switch and the engine stops running
completely