4 Setting the energy prices
3.7
Installer settings: Tables to be
filled in by installer
3.7.1
Quick wizard
Setting
Preferential kWh rate power supply [A.2.1.6]
Preferential kWh rate
Space heating/cooling settings [A.2.1]
Unit control method
User interface location
Number of LWT zones
Pump operation mode
Domestic hot water settings [A.2.2]
DHW operation
DHW pump
Thermostats [A.2.2]
Contact type main
Contact type add.
External sensor
Digital I/O PCB [A.2.2.6]
Solar kit
Alarm output
Demand PCB [A.2.2.7]
Demand PCB
Energy metering [A.2.2]
External kWh meter 1
Gas meter
3.7.2
Space heating/cooling control
Setting
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
Set weather-dependent heating
Set weather-dependent cooling
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
Set weather-dependent heating
Set weather-dependent cooling
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type
Savings mode [A.6.7]
Savings mode
Electricity price [7.4.5]
Elec price
Operation manual
18
Default
Fill in...
0 (No)
2 (RT control)
1 (In room)
0 (1 LWT
zone)
2 (Request)
Depends on
model
0 (No)
2 (H/C
request)
2 (H/C
request)
0 (No)
0 (No)
0 (Normally
open)
0 (No)
0 (No)
0 (No)
Default
Fill in...
1 (Weather
dep.)
35/60/15/−10
18/22/35/20
0 (Fixed)
35/60/15/−10
8/12/35/20
1 (Yes)
0 (Quick)
0
(Economical)
20/kWh (High)
20/kWh
(Medium)
15/kWh (Low)
Setting
Fuel price [7.4.6]
Fuel price
3.7.3
Domestic hot water control [A.4]
Setting
Type
Maximum setpoint
INFORMATION
When the DHW tank booster mode is active, the risk of
space heating/cooling and capacity shortage comfort
problems is significant. In case of frequent domestic hot
water operation, frequent and long space heating/cooling
interruptions will happen.
3.7.4
Contact/helpdesk number [6.3.2]
Setting
Contact/helpdesk number
4
Setting the energy prices
If your system's savings mode is set to Economical, it allows you to
set:
▪ a fixed gas price
▪ 3 electricity price levels
▪ a weekly schedule timer for electricity prices.
The savings mode is set by the installer. Refer to the installation
manual for more information.
Example: How to set the energy prices on the user interface?
Price
Gas: 5.3 euro cent/kWh
Electricity: 12 euro cent/kWh
4.1
To set the gas price
1 Go to [7.4.6]:
> User settings > Preset values > Fuel price.
2 Use
and
to set the correct price.
3 Press
to confirm.
INFORMATION
▪ Price value ranging from 0.00~290 valuta/MBtu (with 2
significant values).
▪ Price value ranging from 0.00~990 valuta/kWh (with 2
significant values).
Default
Fill in...
8.0/kWh
Default
Fill in...
2 (Scheduled
only)
Depends on
model
Default
Fill in...
—
Value in breadcrumb
[7.4.6]=5.3
[7.4.5]=12
RHYHBH05AA + RHYHBH/X08AA
ROTEX HPU hybrid heat pump module
4P353066-1B – 2013.10