3 Operation
3.2.2

Status icons

Icon
Space operation mode = Heating.
Space operation mode = Cooling.
Heat pump (compressor) operation or boiler
operation. This symbol is related to the home page.
Desired room temperature = preset value (Comfort;
daytime).
Desired room temperature = preset value (Eco;
nighttime).
▪ On the room temperature home page: Desired
room temperature = according to the selected
schedule.
▪ On the DHW tank temperature home page:
DHW tank mode = Scheduled mode.
DHW tank mode = Reheat mode.
DHW tank mode = Scheduled + reheat mode.
At the next scheduled action, the desired temperature
will increase.
At the next scheduled action, the desired temperature
will NOT change.
At the next scheduled action, the desired temperature
will decrease.
The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.
The system will produce domestic hot water for the
indicated number of persons.
The DHW tank booster mode is active or ready to be
activated.
Quiet mode is active.
Holiday mode is active or ready to be activated.
Child lock mode and/or function lock mode is active.
Boiler operation.
Heat pump (compressor) operation.
Boiler and heat pump (compressor) operation.
The disinfection mode is active.
A malfunction occured. Press
information about the malfunction.
Weather-dependent mode is active.
User permission level = Installer.
Defrost/oil return mode is active.
Hot start mode is active.
Emergency operation is active.
INFORMATION
Boiler operation does NOT necessarily imply burner
operation. When a heating demand is sent to the boiler,
boiler operation ( ) is continuous, but the burner will ONLY
operate alternately.
Operation manual
14
Description
to display more
3.3

Space heating/cooling control

3.3.1

Setting the space operation mode

To set the space operation mode
1 Go to [4]:
> Operation mode.
2 Select one of the following options and press
If you select...
Then the space operation mode is...
Heating
Always heating mode.
Cooling
Always cooling mode.
Automatic
Automatically changed by the software
based on the outdoor temperature
(and depending on installer settings
also the indoor temperature), and
taking monthly restrictions into
account.
Note: Automatic changeover is only
possible under certain conditions.
To restrict automatic changeover operation mode
1 Go to [7.5]:
> User settings > Allowed operation mode.
2 Select a month and press
3 Select Heating only, Cooling only or Heating/Cooling, and press
.
3.3.2

Using the room temperature home page

Typical room temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. To switch between home pages, go
to [7.1.3]:
> User settings > Display > User profile.
User profile = Basic
To read out the actual and desired room temperature
1 Go to the room temperature home page (Room).
You
can
read
Result:
2 Press
.
Result: You can read out the desired temperature.
To temporarily overrule the room temperature schedule
1 Go to the room temperature home page (Room).
2 Use
or
to adjust the temperature.
To change the mode from scheduled to preset value
Prerequisite: User profile = Detailed.
1 Go to the room temperature home page (Room).
2 Press
or
to select a preset value ( or ).
Result: The mode will return to Scheduled according to the overrule
period.
:
.
User profile = Detailed
out
the
actual
temperature.
RHYHBH05AA + RHYHBH/X08AA
ROTEX HPU hybrid heat pump module
4P353066-1B – 2013.10