DC Application
The DC receptacle may be used for charging 12 volt automotive-type batteries
only.
NOTE:
In DC operation, turn the Eco Throttle switch to the OFF position.
1. Connect the charging cable to the DC receptacle of the generator and then to
the battery terminals.
• To prevent the possibility of creating a spark near the battery, connect
charging cable first to the generator, then to the battery. Disconnect
cable first at the battery.
• Before connecting charging cable to a battery that is installed in a
vehicle, disconnect the vehicle's battery cable. Reconnect the vehicle's
battery cable after the charging cables are removed. This procedure will
prevent the possibility of a short circuit and sparks if you make
accidental contact between a battery terminal and the vehicle's frame or
body.
CAUTION:
• Do not attempt to start an automobile engine with the generator still
connected to the battery. The generator may be damaged.
• Connect the positive battery terminal to the positive charging cord. Do
not reverse the charging cables, or serious damage to the generator and/
or battery may occur.
34
CHARGING CABLE
(Optional parts for all types,
except U type)