Parallel operation

Please read the item ''GENERATOR USE'' before connecting any equipment to be
used.
Use only a special cable for parallel operation (sold separately).
Most appliance motors require more than their rated wattage for startup. Make
sure the electrical rating of the tool or appliance does not exceed the maximum
power rating of the generator.
Maximum power in parallel operation is: 2.0 kVA
For continuous operation, do not exceed the rated power.
Rated power in parallel operation is: 1.8 kVA
In either case, the total power requirements (VA) of all appliances connected
must be considered.
CAUTION:
Substantial overloading that continuously lights the Overload indicator
(red) may damage the generator. Marginal overloading that temporarily
lights the Overload indicator (red) may shorten the service life of the
generator.
PARALLEL OPERATION SOCKETS
SPECIAL CABLE FOR
PARALLEL OPERATION
(SOLD SEPARATELY)