• If the settings are wrong, or if the charger detects a problem, an audio signal is emitted and
the appropriate information is shown on the display (see chapter 16).
You can stop the audio signal by pressing the "Batt Type/Stop" key. You then return to the
previous configuration menu.
If you do not, the following display appears (example):
S:3SER
S:3SER
S:3SER
S:3SER
S:3SER
CONFIRM (ENTER)
CONFIRM (ENTER)
CONFIRM (ENTER)
CONFIRM (ENTER)
CONFIRM (ENTER)
The value "S" shows the number of cells that you have configured in the menu.
The value "R" shows the number of cells that the charger has recognised.
If these two numbers do not match, please check the settings on the charger
and check the battery itself. It may be that the LiPo battery has been completely
discharged, or a cell may be defective. In this case, the battery should not be
charged, as there is a risk of fire and explosion!
You can return to the previous configuration menu using the "Batt Type/Stop"
key.
• If the two numbers match, you can start the charging process by quickly pressing the "Start/
Enter" key.
Once the charging process has been started, various pieces of information about the current
charging progress are displayed.
Example:
Number of cells
Li3S 1.2A 12.59V
Li3S 1.2A 12.59V
Li3S 1.2A 12.59V
Li3S 1.2A 12.59V
Li3S 1.2A 12.59V
CHG 022:43 00682
CHG 022:43 00682
CHG 022:43 00682
CHG 022:43 00682
CHG 022:43 00682
Current charging duration
• Once the charging process has been completed, an audio signal is emitted.
If you wish to terminate the charging process beforehand, press the "Batt Type/
Stop" key.
R:3SER
R:3SER
R:3SER
R:3SER
R:3SER
Charge current
Charge capacity in mAh
Battery voltage
51