5
Cable transition STV-KÜ-T1 FT (sash part)
To transmit the current from the frame to the sash, so-called cable transitions (de-
tails in the following text) or so-called tappet contacts (see separate installation,
operating and maintenance instructions for tappet contact) can be used.
CAUTION!
The cable transitions must be installed in the safe area (e.g. installed concealed in
the airgap) and protected against manipulation.
(
)
6), 7), 8)
Frame part 1 with 4 m cable and cable end sleeves or alternatively frame part 2
with 0.6 m cable and plug for frame power supply
Installed concealed in the airgap
Electric interface between sash and frame with 6 wires
Colour silver/grey
No routing for > 11 mm airgap needed, suitable for PVCu and aluminium entrance
doors (depends on the system), with appropriate routing it is suitable for wooden
doors
Recommendation: It is recommended that the cover plate (depends on the face-
plate and the material type of timber, PVCu/plastic or aluminum) conceals the
routing for the required cable reserves to prevent possible cable damage.
Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen
Subject to technical changes
Plug-in and concealed in cable transition
Inserted by plug-in function, with retaining screws 3 x 20 mm
(contained in packaging sash part)
Sash part with spring sleeve in different versions
STV-KÜ-T1 FT 2 M with 2 m cable + plug for motor
1)
STV-KÜ-T1 FT 3,5 M with 3.5 m cable + plug for motor
2)
STV-KÜ-T1 SET FT INTEGR-EAV FT 1 M + KABEL 3 M with 1 m
3)
cable, end of the cable with 8-pole plug (for control unit ekey
home integra) + connecting cable for motor 3-wire
STV-KÜ-T1 SET FT ZK-EAV FT 4 M + KA 3,5 M with 3.5 m
4)
cable + 5-pole plug for connection with Y-cable INSIDE EAV
0.5 m + Y-Kabel INSIDE EAV 0.5 m
STV-KÜ-T1 SET FT ZK-SO + EAV FT 1M + KABEL 3 M, Set
5)
with sash part KÜ-T1-SOMMER-EAV + connecting cable for
motor SOMMER 3 m
21
Print-no. 504 474 4
01/2017
General
information
Important
information
Product
description
Installation
Operation
Programming
Maintenance
and care
Errors
Troubleshooting
Technical
specifications
Accessories
www.winkhaus.de
EN
1
2
3
4
5
6
7
8

Publicité

Table des Matières
loading

Table des Matières